Controller CLI Commands (X330WAN-2DS1 Only)

 

 

Parameters

 

line

The controller recovers the external clock from the line and provides

 

the recovered clock to the internal (system) clock generator. This is

 

the default value.

internal

The controller synchronizes itself to the internal (system) clock.

Note: Only one E1/T1 controller at a time can recover the network clock and distribute it to the internal clock generator.

Example

X330WAN-2DS1-1(config-controller:1)# clock source internal

X330WAN-2DS1-1(config-controller:1)# no clock source

controller

Use the controller command to enter the specified controller's mode.

Note: You can not configure one controller as E1 and the other as T1.

Syntax

controller { e1 t1 } <port>

Parameters

e1

An E1 port.

t1

A T1 port.

port

The number of the port that is being configured.

Example

X330WAN-2DS1-1(configure)# controller E1 2

Avaya X330WAN User’s Guide

119

Page 141
Image 141
Avaya X330WAN manual Controller