Installing an X330WAN Module into an Avaya P330 Switch

5Follow the post-installation checks, as described in "Power On Self Test" on page 11.

Power On Self Test

When you power up the Avaya P330 switch with a X330WAN module inserted, both the P330 switch and the X330WAN perform a self test. This test takes about 40 seconds to complete, and includes:

Checksum tests of boot and system areas of Flash memory

System memory tests

MAC address verification test

System timer test

CAM (Contents Addressable Memory) tests

Console Port tests

Internal packet forwarding tests

Switch and expansion module ASIC (Application Specific Integrated Circuit) tests

Switch and expansion module ASIC memory tests

Expansion module interface tests

Expansion module packet forwarding tests

After you insert an X330WAN access router module into a powered P330 switch, causing a reset, or after a power cycle of the host P330 switch, the X330W-2DS1 startup sequence is as follows:

1Initially all LEDs light for 15 seconds and then switch off.

2The ALM LEDs light for 15 seconds and then switch off.

3The TST LEDs lights for 15 seconds and then switch off.

4At this point, the ALM LED lights again if there is no line signal detected on the E1/T1 ports. If a signal is detected on the line, the SIG LEDs light and the ALM LEDs switch off.

The X330W-2USP startup sequence is as follows:

1All LEDs light for 15 seconds, then switch off.

2All LEDs remain off for 15 seconds.

3The OPR LED lights and remains on.

Note: LED Number 51 on the Avaya P330 switch should be ON during the self-test procedure.

The X330WAN module must be inserted completely for the P330 switch to successfully reset.