Chapter 6 X330WAN CLI Commands

invert txclock (X330WAN-2USP)

Use the invert txclock command to invert the transmit clock signal (TxC) from the DCE. This signal is used by the DTE in transmitting data. The no form of this command returns the signal to ‘not inverted’.

Syntax

[no] invert txclock

Example

X330WAN-2USP(configure)# invert txclock

load-interval (Serial interface context)

Use the load-intervalcommand to set the load-calculation interval for an interface.

The syntax for this command is:

load-interval <seconds>

seconds DTR low time, in milliseconds (an integer from 30 to 600). The default is 300.

Note: The load interval must be in increments of 30 seconds.

Example

X330W-2USP-1(super-if:Serial2)# load-interval 60

loopback (X330WAN-2USP Serial interface context)

Use the loopback command to activate a Loopback signal on the Serial interface. This action creates a loop in the DCE. The no form of this command deactivates the loopback (default).

Syntax

[no] loopback

Example

X330W-2USP-1(super-if:Serial2)# loopback

134

Avaya X330WAN User’s Guide

Page 156
Image 156
Avaya Invert txclock X330WAN-2USP, Load-interval Serial interface context, No invert txclock, Load-interval seconds