magicolor 330 - Base Engine Service Manual 5-21
Primary Fault Isolation Procedures
5.9 - Spots, continued
Step Actions and Questions Yes No
6
AUGER ASSEMBLY INSPECTION
With the Belt Cleaner Assembly rem oved, inspect the Belt C leaner
end of the Auger.
Is the Auger clogged?
Go to step 7 Clean the
printer interior
7
AUGER DRIVE TEST
1. Remove the Rear Cover (RRP 9.4).
2. With the Belt Clea ner Assembly removed watch the Auger
Drive Gear as you hand rotate the Paper Handling Motor.
Does the Fuser Drive Asse mbly rotate the Au ger Drive Gear?
Go to step 8 Replace the
Fuser Drive
Assembly
(RRP 9.110)
8
AUGER SPRING TEST
As you hand rotate the Paper Handling Motor place your finger
inside the Auger opening and feel the movement of the Auger
Spring.
Does the Auger Spring rotate whe n you hand rotate th e Paper
Handling Motor?
Go to step 9 Replace the
Auger Assem-
bly (RRP 9.77)
9
WASTE TONER BOX GEAR INSPECTION
Remove the Waste Toner Box (RRP 9.49) and inspect Box.
Is the Waste Toner Box clean, not leaking toner, and not obvi-
ously damaged?
Replace the
Xerographic
Cartridge (RRP
9.48)
Replace the
Waste Toner
Box (RRP
9.49)