magicolor 330 - Base Engine Service Manual 3-47
Primary FIPS: Error Messages

3.42 - Error Message: Adjust Opt1 Bin

There is a problem with Feeder 1.
Logic control on the MCU PWB did not detect the OPT1 Bin installed in Feeder 1.
Step Actions and Questions Yes No
SUSPECT COMPONENTS
The following components are associated with this specific prob-
lem. One or more of these components may have failed partially
or completely. If you cannot isolate the problem using this FIP,
replace each component listed below, one at a time, until the prob-
lem disappears.
• Wiring and connectors linking the LCIF to the Base Engine
• Wiring and connectors linking the components
1OPT1 BIN INSPECTION
1. Remove the Paper Tray from Feeder 1.
2. Inspect the Size Act uators at the rear of the Tray.
Are the Actuators intact and free of damage?
Go to step 2 Replace the
OPT1 Bin.
2Replace the Feeder 1 Size Switch Assembly (RRP 9.13)
Does the error message still appear?
Go to step 3 Problem
solved
3Replace the Feeder PWB (LCIF RRP 6.10)
Does the error message still appear?
Go to step 4 Problem
solved
4Replace the MCU PWB (LCIF RRP 6.123)
Does the error message still appear?
Go to suspect
components
Problem
solved