magicolor 330 - Base Engine Service Manual 9-83
Removal and Replacement Procedures
RRP 9.39 Registration Chute Assembly (PL5.1.6)
Removal
1. Slide the Main Paper Han dling Assembly out of the printer.
You do not need to remove the Assembly.
2. Remove the E ring securing the rea r arm of the Registration Chute Assembly to the Main Paper Han-
dling Assembly.
3. Remove the screw securing the ground wire to the Assembly and remove the wire.
4. Open the Registration Ch ute Assembly.
5. Slide the Chute Assembl y to the rear and remove the Assembly.
Replacement
1. Slide the Main Paper Han dling Assembly out of the printer.
2. Slide the rear arm of the Registration Chute Assembly onto the metal pivot that is located at the rear of
the Main Paper Handling Assembly.
3. Slide the rear arm far enough onto the rear arm so you can slide the front arm onto the fron t metal
pivot.
4. Slide the Registration Chute Assembly forward so the E ring channel on the rear pivot is behind the
rear arm.
5. Use an E ring to secure th e rear arm of the Registration Chute Assembly to the Main Paper Handling
Assembly.
6. Reinstall the ground wire t o the Assembly and use one screw to secure the wire.
7. Close the Main Paper Handling Assembly.