3-58 magicolor 330 - Base Engine Service Manual
Primary FIPS: Error Messages

3.54 - Error Message: Replace BTR2

BTR2 has reached end of life.
Logic control on the MCU PWB detected that BTR2 has processed over 100,000 images.
Step Actions and Questions Yes No
SUSPECT COMPONENTS
The following components are associated with this specific prob-
lem. One or more of these components may have failed partially
or completely. If you cannot isolate the problem using this FIP,
replace each component listed below, one at a time, until the prob-
lem disappears.
• Wiring and connectors linking the components
1Replace the 2nd BTR Assembly (RRP 9.75)
Does the error message still appear?
Go to step 2 Problem
solved
2Replace the MCU PWB (RRP 9.123)
Does the error message still appear?
Go to suspect
components
Problem
solved