magicolor 330 - Base Engine Service Manual 9-183
Removal and Replacement Procedures
RRP 9.89 Fuser Exit Sensor (PL9.2.25)
Removal
1. Remove the Main Fuser Assembly (RRP 9.81).
2. Raise the Upper Guide Assembly so it is out of the way.
3. Remove the screw secu ring the Lower Exit Guide to the Main Fuser Assembly.
4. Slide the Lower Ex it Guide to the to free the three latches that are located under the Guide and remove
the Guide from the Main Fuser Assembly.
5. Disconnect P/J 75 from the Fuser Exit Sensor.
6. Squeeze the latches securing the Fuser Exit Sensor to the Main Fuser Assembly and remove the Sen-
sor.
Replacement
1. Position the Fuser E xit Sensor against the cutouts in the Main Fuser Assembly.
2. Press the Fuser Exit Se nsor into the cutouts unit the latches snap into place.
3. Reconnect P/J 75 to the Fus er Exit Sensor.
4. Use a lightly sticky tape back the four Pr essure Roll Fingers that are attached to the Lower Exit Guide.
5. Make sure the Fuser Ex it Sensor Actuator is still in place on the Lower Exit Guide.
6. Press and hold the Fuse r Exit Sensor Actuator while you reinstall the Lower Exit Guide.
7. Reinstall the Lower Exit Guide onto the M ain Fuser Assembly by first positioning the Guide slightly to
the left of center, then sliding the Guide to the right so the three latches under the Guide engage the
three slots in the Main Fuser Assembly.
8. Release the Fuser Exit Sensor Actuator and ch eck the action to make sure it moves smoothly and is
positioned between the arms of the Fuser Exit Sensor.
9. Remove the tape from the four Pressure Roll Fingers, make sure the re is no tape residue left on the
Fingers and make sure they all ride on the surface of the Press Roll.
10. Use one screw to secure the Lower E xit Guide to the Main Fuser Assembly.
11. Lower the Upper Guide Assembly.
12. Reinstall the Main Fuser Assemb ly (RRP 9.81).