magicolor 330 - Base Engine Service Manual 9-187
Removal and Replacement Procedures
RRP 9.91 Exchange Chute (PL9.3.10)Removal
1. Remove the Main Fuser Assembly (RRP 9.81).
2. Place the Fuser Tray on a flat and sta ble work surface.
3. Remove the screw securi ng the Exchange Stopper-R to the Tray and remove the Stopper.
4. Pull the rear of the Exch ange Chute free from the Exchange Solenoid.
5. Remove the screw securi ng the Exchange Stopper-F to the Tray and remove the Stopper.
6. Pull the front of the Exchange Chute, al ong with the Exchange Spring, free from the notch in the front
of the Fuser Tray and remove the Exchange Chute.
Replacement
1. Insert the front of the Exch ange Chute, the straight end, into the notch in the front of the Fuser Tray.
2. Insert the rear of the Exchange Chute, the forked end, into the notch in the rear of the Fuser Tray, mak-
ing sure the fork engages the Exchange Solenoid plunger.
3. Reinstall the Excha nge Spring onto the front end of the Exchange Chute, making sure the straight end
of the Spring rests on top of the Chute arm and the hooked end of the Spring is captured b y the tab
extending from the Fuser Tray.
4. Reinstall the Exchange Sto pper-F to the Tray and use one screw to secure the Stopper.
5. Reinstall the Exchange Sto pper-R to the Tray and use one screw to secure the Stopper.
6. Reinstall the Main Fuser Assembly (RRP 9.81).