magicolor 330 - Base Engine Service Manual 3-45
Primary FIPS: Error Messages

3.40 - Error Message: Call for Service Fuser Lamp

There is a problem with the Fuser Lamp control.
Logic control on the MCU PWB detected that the Fuser Lamp remained on longer than the specified time.
Step Actions and Questions Yes No
SUSPECT COMPONENTS
The following components are associated with this specific prob-
lem. One or more of these components may have failed partially
or completely. If you cannot isolate the problem using this FIP,
replace each component listed below, one at a time, until the prob-
lem disappears.
• Main Fuser Assembly (RRP 9.81)
• Wiring and connectors linking the components
1Replace the Temperature Sensor Assembly (RRP 9.88)
Does the error message still appear?
Go to step 2 Problem
solved
2Replace the MCU PWB (RRP 9.123)
Does the error message still appear?
Go to step 3 Problem
solved
3Replace the LVPS Assembly (RRP 9.119)
Does the error message still appear?
Go to suspect
components
Problem
solved