7-4 magicolor 330 - Base Engine Service Manual
Getting Connected to Engine Diagnostics
Extent; select "ENTIRE SCREEN"
Wide; select "OFF"
Select "F5" to continue on to the next menu
Protocol; select "ASCII TEXT"
Maximum send rate; select "AT BAUD RATE"
How many secs/10; select "1"
End of line; select "CR-LF"
Convert null lines to a space; select "NO"
Remove escape sequences; select "NO"
Stop upon receiving; leave blank
The setup procedure is now completed, select "Esc" to end setup.
5. Power "ON" the printer (wait fo r the printer to finish it’s power up sequence before proceding)
VTERM will automatically connect to the serial cable through the Com port.
6. Press the "Ctrl" & "D" keys simultaneously to reach the "<DBG> prompt
7. Type "edg" for the Main Menu to appear
You are now ready to run the Engine Diagnostics (refer to section 9).
If a test result becomes suspect during the Engine Diagnostic testing, the printer should be turned "OFF", and then
steps 5 through 7 should be repeated. After the printer has powered back up, repeat the suspect test to confirm the
results of the initial test.