Maintenance 175
The
The Power Up
Table 40 describes the items the system checks during the ICB
Table 40
ICB self-test sequence
Item tested | Description |
|
|
Reads and stores processor ID. Runs processor | |
|
|
SDRAM | Checks the amount of SDRAM installed. Performs read/write test. |
|
|
System I/O Controller | Performs read/write test on selected registers. |
|
|
PCMCIA Controller | Performs read/write test on selected registers. |
|
|
Tests shared memory and performs loopback test over | |
|
|
Checks the presence of DSP cards and initiates diagnostic tests on DSP | |
| cards, if present. |
|
|
PCMCIA hard drive | Checks the presence of the hard drive and checks the configuration |
| information. |
|
|
PCMCIA Flash card | Checks the presence of Flash memory and checks configuration |
| information. |
|
|
Loopback MPU | Sends data to the transmit area of the MPU buffers and resends it back |
| for the receive area to the same buffer. |
|
|
Loopback DSP | Sends data to the transmit area of the MPU buffers and resends it back |
| for the receive area to the same buffer. |
|
|
Signaling Tests
Signaling tests check the x12 interfaces in both directions between the card and system. This test includes reception of the messages from the system and sending messages to the system. The Signaling test is executed from Overlay 30 using the UNTT command (Meridian 1/CS
Nortel Integrated Conference Bridge Service Implementation Guide