Installation and configuration 49
Enter the CS 1000 definitions for the Phantom TN in LD 10 as follows:
1The specific TN and DN vary by site.
Those variables are represented by “x” in Figure 9 on page 49.
2CFXA is the Class of Service (CLS) that enables Call Forwarding.
3The last four variables in the screen (under FTR) are the main ACD DNs in LD 23.
Figure 9
Phantom TN definitions (LD 10)
DES | MICB | x | xx xx | PHANTOM |
TN | xxx | |||
TYPE | 500 |
|
|
|
CDEN | 4D |
|
|
|
CUST | 0 |
|
|
|
WRLS | NO | x | MARP |
|
DN | xxxx |
| ||
AST | NO |
|
|
|
IAPG | 0 |
|
|
|
HUNT | 1 |
|
|
|
TGAR |
|
|
| |
LDN | NO |
|
|
|
NCOS | 0 |
|
|
|
SGRP | 0 |
|
|
|
RNPG | 0 |
|
|
|
XLST | 0 |
|
|
|
SCI |
|
|
| |
SCPW | NO |
|
|
|
SFLT |
|
|
| |
CAC | 3 |
|
|
|
CLS |
| CTD |
| DTN | FBD | XFD | WTA | THFD | FND | HTD | ONS |
LPR |
| XRD |
| CWD | SWD | MWD | LPD | XHD | CCSD | LND | TVD |
CFTD | SFD |
| MRD | C6D | CNID | CLBD AUTU |
|
|
| ||
ICDD | CDMD | LLCN | EHTD | MCTD | AGTD CLTD | LDTD | ASCD |
| |||
GPUD | DPUD | CFXA | ARND | OVDD | MIND | ||||||
MBXD | CPFA | CPTA | HSPD | UDI | ACC | HBTD | DDGA | NAMA | |||
NRWD | NRCD | NROD | SPKD | CRD | PRSD MCRD |
|
|
| |||
EXRO | SHL |
| ABDD | CFHD | DNAA | FAXD |
|
|
|
| |
CWND | USRD | BNRD | OCHD | RTDD |
|
|
|
| |||
PLEV | 02 |
|
|
|
|
|
|
|
|
|
|
AACS | NO |
| 0 |
|
|
|
|
|
|
|
|
MLWU_LANG | <ACD DN> |
|
|
|
|
| |||||
FTR | DCFW | 12 |
|
|
|
|
|
The next step is to configure ICB ports as digital sets.
Table 7
LD 11 – Configure ICB ports as digital sets
Prompt | Response | Description |
|
|
|
REQ | NEW | Add new data. |
|
|
|
TYPE | 2616 | Digital telephone set M2616. |
|
|
|
Nortel Integrated Conference Bridge Service Implementation Guide