Installation and configuration 71

Procedure 12

Set up CLI access from the maintenance terminal

1Specify the VT-100 type terminal interface characteristics to make sure they are compatible with the ICB RS-232 interface.

2Set the interface parameters as follows:

Transmission speed: 9600 bps

Data bits: 8

Stop bit: 1

Parity: No

Flow control: none

Note: Do not use XON/XFF flow control.

This procedure is now complete

The next step is to define IP parameters using the CLI.

Procedure 13

Configure initial card parameters using the CLI

1Enter the key-code.

2Enter the card feature (Basic or Advanced).

3From the VT-100 type terminal press the Enter key.

The logon window appears.

4At the login prompt, enter the following: admin

The default password is blank. Press the Enter key at the password prompt.

5Access the System Administration menu. Enter:

SA

The System Administration menu opens.

6Access the System Attributes Editor. Enter:

SY

The System Attributes Editor opens.

7Enter the following IP attributes for the ICB card:

IP address – The internet protocol address which has the same format as the gateway address.

Subnet mask – The part of the IP address which represents a subnetwork within a network. The subnet mask has a format of XXX.XXX.XXX. XXX,