Maintenance 181

Table 46

ICB CLI command summary (Continued)

Menu and command

Items and commands

 

 

Port maintenance:

Port Status Display: PS

PM

Displays status of all ICB ports as follows: Idle, Dialing_out, Ringing,

 

Talking, or Disabled.

 

Port Disconnect: PD

 

Disconnect a specific port from the conference.

 

 

Report Generation:

Meetings Log Browser: ML

RG

Browse the meeting log (see “CLI Meetings Log Report” on page 199).

 

Log ordering: ORDer_mlog

 

Prompts for the same parameters (year, month, day) and displays the log

 

contents sorted by access DN. The advantage is that all records of each

 

specific conference appear together.

 

 

ICB fault isolation and correction

Alarm clearing procedures for the ICB are the identical to those for other IPE cards.

FOR MORE INFORMATION

Refer to the following documents for additional information about how to clear alarms:

Meridian 1 Fault Clearing

Meridian SL-100– Alarm Clearing Procedures

Table 47 describes ICB service problems and the test procedures used to solve these problems.

Note: If the problem cannot be solved after using all available diagnostic tools and test procedures, list the symptoms observed and contact your Nortel Networks representative.

Table 47

ICB equipment problems

Symptoms

Diagnosis

Solution

 

 

 

Red card LED on

Card is disabled or

Check the card status and perform a self-test on the

the ICB is

faulty.

card by pulling it out and plugging it back in, or from the

permanently on.

 

CLI using the cr command under the SMaint menu.

 

 

 

Nortel Integrated Conference Bridge Service Implementation Guide

Page 181
Image 181
Nortel Networks 555-4001-135 manual ICB fault isolation and correction, ICB equipment problems, Symptoms Diagnosis Solution