Maintenance 181
Nortel Integrated Conference Bridge Service Implementation Guide
ICB fault isolation and correction
Alarm clearing procedures for the ICB are the identical to those for
other IPE cards.
Table 47 describes ICB service problems and the test procedures used
to solve these problems.
Note: If the problem cannot be solved after using all available
diagnostic tools and test procedures, list the symptoms observed and
contact your Nortel Networks representative.
Port maintenance:
PM
Port Status Display: PS
Displays status of all ICB ports as follows: Idle, Dialing_out, Ringing,
Talking, or Disabled.
Port Disconnect: PD
Disconnect a specific port from the conference.
Report Generation:
RG
Meetings Log Browser: ML
Browse the meeting log (see “CLI Meetings Log Report” on page 199).
Log ordering: ORDer_mlog
Prompts for the same parameters (year, month, day) and displays the log
contents sorted by access DN. The advantage is that all records of each
specific conference appear together.
Table 46
ICB CLI command summary (Continued)
Menu and command Items and commands
FOR MORE INFORMATION
Refer to the following documents for additional information about
how to clear alarms:
Meridian 1Fault Clearing
Meridian SL-100 – Alarm Clearing Procedures
Tabl e 47
ICB equipment problems
Symptoms Diagnosis Solution
Red card LED on
the ICB is
permanently on.
Card is disabled or
faulty.
Check the card status and perform a self-test on the
card by pulling it out and plugging it back in, or from the
CLI using the cr command under the SMaint menu.