222 Upgrades
Procedure 50
Stand-alone card to primary card
1Access the ICB Installation Wizard: Step 1 – Basic Card Settings window (see “Step 1 – Basic Card Settings” on page 73). In the “Type” field, select the radio button “Dual Card – Primary.”
2Click the Submit & Continue button.
If 10 DN pairs are configured, the system deletes one automatically. The ICB first attempts to delete a DN pair that has no conferences scheduled against it. If no such DN pair is found, the ICB deletes the DN pair with the least number of conferences using it. All associated conferences are deleted.
Note: A DN pair used by a permanent conference is not deleted.
If a DN pair is deleted in
3The system displays Step 2 of the Installation Wizard (see “Step 2 – Access Numbers” on page 76). If the automatic change, as described above, took place, this is reflected in the DN table. If the direct access dialing mode is used, only nine DNs appear.
4Click the Submit & Continue button.
5The system displays Step 4 of the Installation Wizard (see “Step 4 – Dual Card Meetings” on page 77).
If a DN pair was automatically deleted as described above, it appears in the fields “Conference access number” and “Chairperson number in primary card.” You can change these numbers; they must be configured in the Meridian switch as well.
Fill in all the fields as described in the installation instructions, and click the Finish button.
6Logout of this card and proceed with the Meridian switch configuration change (see Procedure 51).
This procedure is now complete
Procedure 51
Meridian switch configuration changes
1If a DN pair was deleted from the secondary or primary card, delete it from the switch datafill.
2Configure the DNs defined in the Installation Wizard Step 4 window of the primary ICB. Define them as described in the
This procedure is now complete