Installation and configuration 57

3Define the ICB conference and chairperson bridge DNs. Refer to Figure 16 on page 58. This step provides the following:

a Main DN for conference ACD groups to access the ICB agents on the card.

b Conference DNs and Chairperson DNs. c TUI DN and Assistant DN.

d Single number access conference and chairperson DN.

4Define the night service route from ACDGRP NSROUTE.

The night service DN assigned in table OFRT allows conference and chairperson ACDGRPs to route to the ICB card ACD agents. Table DNROUTE defines the routes. Figure 17 on page 58 shows an example of table OFRT routing to 214 997 1400 (ICB DN) assigned in table DNROUTE.

5Use the following tables and command interfaces (CIs) to datafill the ICB for single-card configuration:

Table LNINV.

Table ACDGRP.

Table ACDSGRP.

Table ACDLOGIN.

Table CUSTACD (optional).

Table ACDENLOG (optional).

Table DNROUTE.

Table OFRT.

Table OFCENG.

Service Orders.

Figure 12

LNINV example

LEN CARDCODE PADGRP STATUS GND BNV MNO CARDINFO

----------------------------------------------------------------------------------------

IPE1 00 0 00 00 5D51AB NPDGP WORKING N NL Y FLXA

Note: Cardcode can also be configured as an 8D02 digital line card.

Figure 13

ACDGRP example

ACDNAME CUSTGRP ACDRNGTH THROUTE NSROUTE PRIOPRO DBG MAXCQSIZ MAXWAIT ACDMIS MSQS DISTRING OBSWTONE FRCNGTSV OPTIONS

----------------------------------------------------------------------------

MICB BNRRCH 12 OFRT 600 OFRT 600 0 Y 2 0 N N NONE N N (ACDDISP 4) (NONIMCUT ) $

Nortel Integrated Conference Bridge Service Implementation Guide

Page 57
Image 57
Nortel Networks 555-4001-135, 553-3001-358 manual Lninv example, Acdgrp example