226 Appendix A: Password security
553-3001-358/555-4001-135 Standard 02.00 July 2006
c Telnet access – After the maximum allowed login attempts, the system
closes the connection. An administrator can define the “new connection
refused” time period.
d TUI access – After three unsuccessful login attempts, the system
This procedure is now complete
disconnects the call.
Password parameters summary
Table 59 shows the ICB Release 4 default login names and passwords.
Table 60 summarizes the security parameters and their defaults.
Tabl e 59
Default login names and passwords
Access type Default login name Default password
User BUI login (multiple users) No default 000000
Administration BUI login (multiple
administrators)
No default (see Note 1) 000000
TUI login (multiple users) No default Equal to BUI password
CLI first level admin (see Note 2)
CLI second level debug
Telnet MICB admin
FTP MICB admin
Note 1: Initially, one administrator account exists: “admin”.
Note 2: The CLI’s default passwords are empty (that is, no password).
Tabl e 60
Security parameters summary
Parameter Range Default value
Minimum login name length 4-10 4
Minimum password length 1-16 4
Maximum password length Hard-coded 16
CLI maximum unsuccessful login attempts 1-10 5
CLI blocking period after “Maximum
unsuccessful login” is exceeded
1-1440 seconds 0
CLI inactivity time-out 1-1440 minutes 15