Polycom RMX 1000 User Guide
allocated by the system. These options are configurable, but none of these settings need to be modified to start a conference.
The conference chairperson or organizer should inform other participants of the conference ID used for the conference, so that they can dial in.
If necessary, set the basic parameters for the conference and add participants or related supplementary information as needed. For more information of configuration, see Creating a Meeting Room.
After completing the setup, click OK. After that, the conference list shows that the new conference is running. If no participant is specified for the
conference, the status is displayed as , until a participant dials in to the conference.
Starting a Conference Using the Remote Control – Conference on Demand
A user can enter the call character string that contains the conference ID through the remote control, and directly start a new conference on RMX 1000. The dialing string can vary according to the user's endpoint type, whether to set the conference password and chairperson password, and whether to invite other participants.
H.323 Endpoint
For an H.323 endpoint, if the endpoint has been registered to the same gatekeeper as RMX 1000, the
<RMX 1000 E.164 prefix>[Conference ID][##Conference password][##Chairperson password][*Participant's E.164 prefix]
Here, the character in the <> symbol is mandatory, and that in [ ] is optional.
For example:
RMX 1000 E.164 prefix: 925
ID of the conference to be created: 1001
The table below shows the strings dialed by the endpoint under different scenarios:
Table 3-2 Dial-in String Rule for H.323 Endpoints - Registered to GK
Scenario
Dial-in String
Create this conference | 9251001 |
|
|
Create this conference and set: |
|
Conference password: 1111 | 9251001##1111##2222 |
Chairperson password: 2222 |
|
|
|
Create this conference and invite: |
|
Participant 1 - E.164: 123 | 9251001*123*321 |
Participant 2 - E.164: 321 |
|
|
|