Chapter 5 – Recording Link
5-2
Right-click the default empty link or configured RSS IP address in the
interface, and then click Properties to display the Recording Link -> General
interface.
General Settings
Figure 5-2 Recording Link - General
The table below explains the detailed meanings of these parameters.
Table 5-1 Parameter Description for Recording Link - General
Parameter Description
RSS 2000 IP
Address Enter the IP address of the RSS 2000 to be connected. This item
is optional if an alias is set in the Alias check box below.
RSS 2000 Alias
Enter the E.164 number or H.323 alias of the RSS 2000 in
accordance with the selected alias type. This item is optional if
the IP address of the RSS 2000 is set.
Note: If the alias is used for recoding call, both RMX 1000 and
RSS 2000 need to be registered to the same gatekeeper.
Alias Type Set the alias type of the RSS 200 0: H.323 or E.164.
DTMF Code Setting
To set the recording control operations and rights for use by connected
endpoints, click the DTMF Codes tab.
Figure 5-3 Recording Link - DTMF Codes