Polycom RMX 1000 User Guide

Table 11-3Gatekeeper Setting

Parameter

Description

 

Set the IP network type for the RMX 1000 system to make

 

a call. You need to set it based on the call type used for the

 

participant's endpoint. It can be set to:

 

ƒ H.323: Only H.323 calls are supported.

IP Network Type

ƒ SIP: Only SIP calls are supported.

ƒ H.323 & SIP: H.323 calls and SIP calls are supported at

 

 

the same time.

 

Settings of the gatekeeper related parameters are

 

available only when the H.323-supporting network type is

 

selected.

 

 

Register to Gatekeeper

Set whether or not to register with the gatekeeper. You must

check this option to set the parameters that follow.

 

 

 

Primary (Alternate)

Indicates whether or not the device is registered with the

Gatekeeper

primary (or alternate) gatekeeper.

 

 

Gatekeeper IP Address

Set the IP address for the primary (or alternate)

gatekeeper.

 

 

 

Gatekeeper Port

The port number for the primary (or alternate) gatekeeper.

 

 

System Prefix/E164.

Set the E.164 number for the system.

 

 

System H.323 Alias

Set the H.323 alias for the system.

 

 

SIP Server

If your network supports Session Initiation Protocol (SIP), you can connect an IP call with SIP.

In the IP Network Services interface, click SIP Server to configure SIP server parameters.

11-5

Page 100
Image 100
Polycom RMX 1000, 3150-16966-002 manual SIP Server, 11-5