CONFIGURING ADVANCED BRIDGING

Bridge Dial Out

CONFIGURING THE DEVICE LIST FOR BRIDGE DIAL OUT

Note: The Configuring Device Level Databases chapter contains the information needed to completely configure an on-node device entry. The following section provides instructions for entering on-node device information specific to the bridge dial out feature.

USING CFGEDIT

1.Select Security from the main menu.

2.Select Device Level Databases from the security menu.

3.Enable the On-node Device Database if it is currently disabled.

4.Select On-node Device Entries from the authentication database menu.

5.Select Add. Provide the device name, as prompted, and continue with device configuration, as described in Configuring Device Level Databases:

Device Table Menu: (Device = "DAN")

1)ISDN

2)Frame Relay

3)X.25

4)Authentication

5)IP

6)IPX

7)AppleTalk

8)Bridge

9)Compression

Select function from above or <RET> for previous menu: 1

6.Under ISDN, select Dial Out Phone Number:

Device ISDN Menu: (Device = "DAN")

1)

ISDN Line Protocol.

"PPP (Point to Point Protocol)"

2)

Base Data Rate.

"64000 bps"

3)

Initial

Data Rate.

"64000 bps"

4)

Maximum

Data Rate.

"128000 bps"

5)

Dial Out Phone Number(s).

""

6)

Subaddress.

""

7)

Profile

Name.

"Default_Profile"

8)

H0 Call

Support

DISABLED

Id of option to change or press

<RET> for previous menu: 5

7.Provide device’s dial out phone number, as prompted.

8.Return to the Device Table Menu, and select Bridge:

Workgroup Remote Access Switch 219

Page 219
Image 219
Cabletron Systems CSX1200, CSX1000 manual Under ISDN, select Dial Out Phone Number