PROBLEM DIAGNOSIS

Remote Device Connectivity

REMOTE DEVICE CONNECTIVITY

Problem:

A remote device is not able to connect to the CyberSWITCH.

Set-up:

The system software should be up and running. (At the administration console: if you are in the Connection Monitor window, exit to the “[System Name] >” prompt.)

1.Enable the call trace messages with the trace on console command.

2.Erase the current system messages using the er console command.

3.In a controlled manner, initiate an ISDN connection from the remote device.

Action:

1.After a connection has been initiated, view the system messages (display system messages by issuing the dr console command). Look for the following call request messages among the system messages:

In - INCOMING CALL Call Id=<call Id> Slot =<slot #> Port=<port #> Chans=<bearer channel map> Ces=<comm endpoint suffix> Rate=<data rate>

Out - CONNECT Call Id=<call Id> Slot=<slot #> Port=<port #> Chans=<bearer channel map> Ces=<communication endpoint suffix> ConnId=<connect Id>

In - CONNECT Call Id=<call Id> Slot=<slot#> Port=<port #> Chans=<bearer channel map> Ces=<communication endpoint suffix> ConnId=<connect Id>

If the system reports these messages, then continue with the next step.

If the system does not report these messages, the remote device is not correctly connecting to the system. Check and verify the configuration of the remote device.

2.If the system displays the following message among the system messages (display system messages by issuing the dr console command),

Security Rejection-Invalid Calling Line Id - <#>

the network is indicating a calling line identifier that is not configured for any valid device in the system Device list. The number “#” indicates the actual number presented by the network.

3.For Remote Bridge Devices:

If the system displays the following messages among the system messages,

Security Rejection - Caller did not negotiate security Security Rejection - No Bridge Address given by caller Security Rejection - Unknown Calling Bridge Security Rejection - No Password given by caller Security Rejection - Invalid Password given Security Rejection - HDLC not supported by the caller

review the system configuration for the Device List. You can also refer to the System Messages chapter for the message meanings and the appropriate actions to be taken.

4.For IP Host Devices:

If the system displays the following messages among the system messages:

IP Call Dropped: ID_RSP was not received from remote

IP Call Dropped: XID was not received from remote

Workgroup Remote Access Switch 389

Page 389
Image 389
Cabletron Systems CSX1200, CSX1000 manual Remote Device Connectivity, Set-up