USER’S GUIDE

To perform a remote upgrade, first upgrade to the latest SSB, if required, then upgrade the OSW. The Release Notes will indicate whether or not the SSB needs to be upgraded.

Note: If, during a remote upgrade, the compressed file set cannot be uncompressed into the Flash File System due to a lack of space, the compressed file set will not be deleted from the Flash File System and the previous version of the OSW will be booted. If the OSW determines there is a compressed file set (a file suffix of .OSW) in the Flash File System, then the following message is logged in the system log:

OSW, <OSWFileName>, found in the Flash File System. The OSW has not been updated from this file due to insufficient Flash File System space. Please delete unnecessary files from the system.

It is possible that you will not have enough room in the \SYSTEM directory to TFTP the upgrade file to the system. In this case:

Delete all files in the directory except nex.bin and iop.bin.

Issue a flash reclaim command to gain the lost space (this will destroy the backup copy of your configuration, you will be unable to issue restore command unless you have saved at least one set of changes).

If the upgrade still fails, delete the nex.bin and iop.bin and again reclaim the space. Your upgrade should now work. IMPORTANT: Do not restart the CyberSWITCH until the upgrade is complete.

If you are upgrading from a previous version of system software, the above message will not be displayed. In this case, the system continually restarts, attempting to install the OSW package each time.

REMOTE UPGRADE OF THE SECOND STAGE BOOT (SSB)

WARNING:

If power is lost on the remote CyberSWITCH during this process, a local upgrade of the SSB may be necessary before the system can again function.

To remotely upgrade the SSB, follow these steps:

1.Telnet to the CyberSWITCH and login as admin.

2.Enable TFTP, the TFTP client, and the TFTP server with admin access rights.

3.Using the TFTP client on the remote workstation, TFTP the recover1 file to the CyberSWITCH in binary mode. Be sure to use the file’s full pathname (for example: D:\CSX1204\US\IPIPX\RECOVER1). The exact method to transfer varies, depending upon your TFTP client.

4.At the system prompt, recover the SSB by issuing the following command:

flash recover

The system will ask you if you are sure you want to remotely recover the SSB, and warn you of the potential risk in case of a power failure while the SSB is being recovered. Answer “yes” to the prompt. The window of vulnerability ends after 5 or 10 seconds, when the system tells you that the SSB was successfully recovered.

78 CyberSWITCH