USER’S GUIDE

CALL RESTRICTIONS

CONFIGURING CALL RESTRICTIONS

Note: Certain restrictions apply to the use of Call Restrictions and Semipermanent Connections. Refer to the Background Information discussion.

USING CFGEDIT

1.Select Call Restrictions from the Call Control Options menu.

2.Follow the onscreen instructions for enabling this feature.

3.The current call restriction configuration will be displayed.

4.Enter the number Id associated with the parameter you want to change.

5.Follow the onscreen instructions for changing the parameter.

USING MANAGE MODE COMMANDS

callrest

Displays the current Call Restriction configuration data.

callrest off

Disables the Call Restriction feature.

callrest on

Enables the Call Restriction feature.

CALL RESTRICTION CONFIGURATION ELEMENTS

STATUS

Allows you to enable or disable the call restriction option.

HOURS CALLS ARE ALLOWED

The allowable hours for outbound calls (inbound calls will always be allowed). Separate each hour by a comma. Ranges are allowed by inserting a dash (-) between the first and last hours in the range. A zero entered by itself will allow no calls during any hour.

Two actions are available if an outbound call is attempted at any other time:

1.The call will not be allowed; a message will be displayed on the LCD, and written to the report log.

2.The call will be allowed; however, a warning will be written to the report log.

320 CyberSWITCH

Page 320
Image 320
Cabletron Systems CSX1000 manual Configuring Call Restrictions Using Cfgedit, Call Restriction Configuration Elements