UPGRADING SYSTEM SOFTWARE

Upgrading Software

5.After the recovery, delete the file by issuing the command: del \system\recover1

6.Recover lost space with the command:

flash reclaim

Console Messages during SSB Upgrade:

Message

Suggested Action

 

 

can’t open recover file

If you entered a filename after the flash recover

 

command, makes sure that the file exists on the system.

 

If you did not enter a filename, make sure that

 

\SYSTEM\RECOVER 1 exists on the system.

 

 

not enough DRAM to

Remove DRAM-greedy activities on the system, such as

create binary image

connections to other devices, compression, and

 

authentication. Reboot if necessary.

 

 

error in recovery file

Make sure that the recover file that you are using is

 

correct. Delete, Recover, and reTFTP if necessary.

 

 

Unable to remotely

Hardware failure in the boot device. Contact your

recover SSB

distributor immediately for a replacement.

 

 

successfully updated

The SSB has been successfully updated.

 

 

REMOTE UPGRADE OF THE OPERATIONAL SOFTWARE (OSW)

To remotely upgrade the operational software, follow these steps:

1.From the PC/workstation, Telnet to the CyberSWITCH and login as admin.

2.Verify that the system is ready to receive TFTP upgrades:

Enter MANAGE MODE by typing manage <RET> at the system prompt.

Using the MANAGE MODE command tftp, verify that:

TFTP feature is enabled

TFTP server is enabled

TFTP server is assigned ADMIN file access rights

Using the MANAGE MODE command fileattr, verify that:

ADMIN has READ/WRITE access to CONFIG files

ADMIN has READ/WRITE access to OTHER files

Exit MANAGE MODE by typing exit <RET>.

3.Using the TFTP client on the remote workstation, TFTP the UPGRADE.OSW file to the CyberSWITCH in binary mode. Be sure to include the file’s full pathname (for example: D:\CSX1204\US\IPIPX\UPGRADE.OSW). The exact method to transfer varies, depending upon your TFTP client.

Note: If you experience a transmission timeout, check the retransmission setting on the TFTP package. A retransmission rate of 10 seconds is usually sufficient; values less than that may not work properly.

Workgroup Remote Access Switch 79

Page 79
Image 79