CONFIGURING OFF-NODE SERVER INFORMATION

ACE Authentication Server

system will send an access request retry if the primary server does not respond. After the configured number of retries, the system will request authentication information from the secondary server if one is configured. The connection will be released if neither server responds to the access requests.

Note: For user level security, the CyberSWITCH’s default Telnet port number is 7000, not the normal default (23).

ACE AUTHENTICATION SERVER

CONFIGURING AN ACE AUTHENTICATION SERVER

Note: In order for the CyberSWITCH to reference ACE server, the following configuration steps must first be completed:

basic IP routing information must be configured for ACE

a LAN Network interface must be configured appropriately for the IP network connected to each LAN port on the system

at least one WAN Network Interface must be configured for ACE to be operable

USING CFGEDIT

1.Select option (4), ACE from the Off-node Server Information menu. If you need guidance to find this menu, refer to the instructions provided in the VRA Manager Authentication Server configuration section. The following screen will be displayed:

ACE Authentication Server Menu:

 

 

Primary (Master) Server

 

 

 

is Not Configured

 

Secondary (Slave) Server

 

 

 

is Not Configured

 

Access Request

 

 

Number of Access Retries

is 3

 

Time between Retries

is 1 second

 

Encryption Method

SDI

 

Source IP address

is Not Configured

ACE Server Options:

 

1)

Primary (Master) Server

 

2)

Secondary (Slave) Server

 

3)

Miscellaneous Information

 

4)

Load ACE configuration file.

 

Select function from above or <RET> for previous menu: 1

2.Select Primary Server and enter the following information:

a.IP address of the Authentication Server

b.UDP port number used by the Authentication Server

3.If your configuration includes an ACE Slave server, then select Secondary Server. Enter its IP address. The UDP port number for the Master and Slave servers will be the same, regardless of which server configuration screen from which it is entered.

Workgroup Remote Access Switch 185

Page 185
Image 185
Cabletron Systems CSX1200, CSX1000 manual Configuring AN ACE Authentication Server