SYSTEM MESSAGES

System Message Summary

Resmem_gettotal: Enabled size <size>, greater than Checksize <size> for <sub name> Internal error that should be reported to Customer Support.

ResMem_Malloc failure for subsystem <sub name>

(size=<size>, type=<type>, class=<class>, ra=<hex return address>)

ResMem_Malloc Size <size> too large for subsystem <sub name> (type=<type>, class=<class> ra=<hex return address>)

ResMem_Malloc Device not registered (ra=<hex return address>) ResMem_Obtainable Device not registered (ra=<hex return address>)

Any of the above three messages indicate that an internal error has occurred that should be reported to Customer Support. The system will restart when this error occurs.

Retrying download of DM card in slot <slot# > in <x> seconds

The system has failed on previous attempts to initialize the Digital Modem card. The system will retry a specific number of times before logging a failure message. Check the hardware and software configuration, reseat the card in its ISA slot, and/or check the MVIP cabling. If the problem persists, contact your Distributor or Customer Support.

Rx Channel Inactivity Detected

No keep-alive frames have been received over an active connection to a remote system. This indicates that the connection or the remote node has failed (or been powered-off) without an indication of the failure from the network. If the event continues, contact your Distributor or Customer Support.

Security Rejection - Bridge Address Security cannot use Authentication Server

Both options (Bridge Address Security and off-node User Authentication) are not supported simultaneously.

Security Rejection - Caller did not negotiate security

Bridge Security is configured. A caller attempted to send device data before (or without) negotiating the Bridge Address security.

Security Rejection - HDLC not supported by the caller

A properly formed Bridge Security negotiation packet was received but the remote bridge indicated that it did not support the HDLC protocol.

Security Rejection - Invalid Calling Line Id - <CLID>

The calling line identifier has not been configured for any valid device in the system Device list. The number <CLID> indicates the actual number presented by the network.

Security Rejection - Invalid Password (<password>) given

A properly formed Bridge Security negotiation packet was received. The bridge is registered in the System Device table and a password was provided, but the password provided did not match the password in the System Device table.

Security Rejection - No Bridge Address given by caller

A normal Bridge Security negotiation packet was received, but did not contain a bridge address. Check configuration. If problem persists, contact your Distributor or Customer Support.