SYSTEM VERIFICATION

Verifying Compression is Operational

VERIFYING COMPRESSION IS OPERATIONAL

1.Make sure compression is enabled on a system-wide basis.

2.Cause a call to be established with a device for which per-device compression is enabled.

3.To verify that compression is in effect with the device, issue the cmp stats <devicename> console command while the connection is in place. If compression is in effect, this command will display the current compression counters and ratios. If compression is not in effect, the command will return an indication that the device is a non-compressed connection. If compression is not in effect, refer to Compression in the Problem Diagnosis chapter.

VERIFYING RESERVED BANDWIDTH IS OPERATIONAL

1.Configure several different combinations of lines and devices.

2.Attempt outbound and inbound calls.

3.Verify the proper success and reject of each.

If there is a problem, check the configuration of the profiles and how they are assigned to each device (refer to the Bandwidth Reservation in the Configuring Call Control chapter).

VERIFYING PPP LINK FAILURE DETECTION IS OPERATIONAL

To verify that Frame Relay’s Link Failure Detection is enabled, a trace can be performed to view the Echo-Request and Reply packets:

1.With the feature enabled, cause a connection to be established.

2.Erase the system log (issue the er command).

3.Issue the trace ppp on console command.

4.Wait for at least the configured Echo Frequency.

5.Display the system log (issue the dr command). If the feature is operational, some frames like those of the following example will be seen:

(I) 16:28:49.71 #C021: Conn=001 OUT-PPP:LCP

ECHO REQ Id=0x50 Len=10

(I)

16:28:49.71

#0000:

3E

03

78

AC

 

(I) 16:28:49.76 #C021: Conn=001 IN -PPP:LCP

ECHO RPLY Id=0x50 Len=10

(I)

16:28:49.76

#0000:

70

18

D0

87

 

(I) 16:28:59.82 #C021: Conn=001 OUT-PPP:LCP

ECHO REQ Id=0x51 Len=10

(I)

16:28:59.82

#0000:

3E

03

78

AC

 

(I) 16:28:59.82 #C021: Conn=001 IN -PPP:LCP

ECHO RPLY Id=0x51 Len=10

(I)

16:28:59.82

#0000:

70

18

D0

87

 

Short of having a faulty PPP link, verifying that the feature detects a failure can be accomplished as follows: