USER’S GUIDE

Mismatch of configured and installed DM card in slot <slot #>

The switch and/or jumper settings on the specified Digital Modem card are not properly set to match how the card is configured in software. Check the hardware and software configuration and restart.

Missing BEARER_CAPABILITY in HOST_CALL_REQUEST

Missing CALLED_NUMBER_IE in HOST_CALL_REQUEST

Missing CHANNEL in HOST_CALL_REQUEST

Missing CHANNEL_ID_IE in HOST_CALL_REQUEST

Missing TN in HOST_CALL_REQUEST

The above Robbed Bit Signaling messages indicate that the system software sent a message to the RBS state machine that the state machine was unable to recognize or the information was incorrect. If this message is displayed in the log messages, contact your Distributor or Customer Support.

MODEM <modem #> of DM card in slot <slot #> is unusable

An attempt was made to perform an operation on a specific modem that had been deleted from the usable list via the modem delete command. Use the modem add command to make the modem usable again, or use a different modem to perform the desired operation.

MODEM CONNECT failed - connect <connect id # >, board <board # >, modem <modem # >

An attempted modem call has failed to connect. Try reconnecting the call again. If this message consistently appears for the same modem number, contact your distributor or Customer Support.

Modem revision on modem <modem #> of slot <slot # > failed

Individual modems on a Digital Modem card are failing. Check the hardware and software configurations, as well as the seating of the card and the MVIP cabling. If all seems in order, contact your Distributor or Customer Support.

Negotiation Failure with Semipermanent device “x”

There was some problem negotiating a connection with device "x." There was no way to send data. This could be an authentication failure or a PPP failure.

Network loop between site1 and site 2

The system detected a WAN loop between the specified sites, so the System will not forward the duplicate frame. Check the System and network configuration for this loop and adjust.

Network requested init but no SPID configured- Slot=<slot # > Port=<port #> Ces=<communication endpoint suffix>

A SPID is required but is not configured on the indicated line. The configuration of the CyberSWITCH or of the switch should be corrected.

Network sent bad Endpoint identifier - Slot=<slot #> Port=<port #> Ces=<communication endpoint suffix>

During terminal initialization, a bad endpoint identifier was received on the indicated line. This message is informational only; your line should continue to operate normally.

Network sent CAUSE - invalid SPID - Slot=<slot # > Port=<port #> Ces=<communication endpoint suffix>

An invalid SPID is configured on the indicated line. The configuration of the CyberSWITCH or of the switch should be corrected.

464 CyberSWITCH

Page 464
Image 464
Cabletron Systems CSX1000 Mismatch of configured and installed DM card in slot slot #, Network loop between site1 and site