Cabletron Systems CSX1000, CSX1200 manual List relnote.txt

Models: CSX1000 CSX1200

1 644
Download 644 pages 26.85 Kb
Page 516
Image 516

USER’S GUIDE

cs

Displays the list of connected devices along with the data rate for each device. The output for this command contains the connection time for each device along with a detailed breakdown (per connection type) of channel usage and available data rates. If there is at least one device connected, the display will look as follows. Note that a “more” mechanism will be used when the number of connected devices exceeds a full screen. If there are no devices connected, the cs command does not produce any output.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[System Name]> CS

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of Channels

 

Data Rate (Kbps)

 

Connect Time

 

 

Device Name

Swi Ded FrR X25 Tot

Swi Ded FrR X25

Tot (hr:min:sec)

 

 

----------------

------------------

---------------------

-----------

 

 

Tokyo

1

0

0

0

1

64

0

0

0

64

00:31:39

 

 

Ann Arbor

1

1

0

0

2

64

64

0

0

128

12:22:18

 

 

New York

4

0

0

0

4

256

0

0

0

256

04:02:22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

dr

Displays reports of system messages. Refer to the chapters titled System Messages or Trace Messages for message definitions.

ds

Displays system statistics. For details on the available system statistics refer to the System Statistics chapter.

list [file name] Displays the indicated file.

For example, to display the Release Notes, enter the following command:

list rel_note.txt

The “more” mechanism is used to view the indicated file. To view the next section of the file, simply press any key (except <escape>). The system will automatically return to the normal system prompt after the entire file has been displayed. If you are viewing the Release Notes, press the <escape> key to exit the release notes and continue with the installation.

If the file name is incorrect, the following message will be displayed:

Cannot find file "file name"

mc

Displays the Connection Monitor screen. This screen provides information on the remote sites to which the system is currently connected. The system updates the display as connections are added or removed.

To display the Connection Monitor screen, Telnet and the terminal emulator must both be set as the same terminal type. Use the term set command to do this.

Note:The mc command is also available if you are remotely connected to the CyberSWITCH by Telnet.

neif

This command will display the system interface table. This table provides information for each of the system’s physical interfaces, including interface name, interface type, slot and port

516 CyberSWITCH

Page 516
Image 516
Cabletron Systems CSX1000, CSX1200 manual List relnote.txt