USER’S GUIDE

X.25 CONNECTIONS

Problem:

An X.25 access is configured, but the x.25 stats command response is:

No X.25 Access configured

Action:

Verify that the proper line and port have been selected.

1.Enter the er command to erase the report log.

2.Enter the trace lapb on command.

3.Wait 20 seconds, then enter the dr command to display the report log. The status log should display a sequence of the following messages:

(I)17:33:35.38 #1067: Out - LAPB RR, Rx Sequence = 1

(I) 17:33:35.38 #0000: 01 31 00 2A

(I)17:33:35.38 #1067: IN - LAPB RR, Rx Sequence = 1

(I)17:33:35.38 #0000: 01 31 A2 00

4.If these messages are not displayed, verify with the service provider that the line and bearer are provisioned for X.25 packet access, and the LAPB addressing format, modulo 8 or 128, is consistent with the line provisioning.

5.If the log contains a sequence similar to the following:

(I)17:33:32.32 #1067: IN - LAPB SABM

(I)17:33:42.32 #1067: IN - LAPB SABM

(I)17:33:52.32 #1067: IN - LAPB SABM

verify with the service provider verify that the line and bearer are provisioned for X.25 packet access, and the LAPB addressing format, modulo 8 or 16, is consistent with the line provisioning.

6.If the log contains a sequence similar to the following:

(I)17:33:32.32 #1067: IN - LAPB SABM

(I) 17:33:32.32 #0000: 03 3F A6 04

(I)17:33:32.32 #1C05: x25 access 1 in state ACCESS UP for event LAPB UP

(E) 17:33:32.32 #1C04: Invalid event for access 1

(I)17:33:32.32 #1C05: x25 access 1 in state ACCESS UP for event X25 DOWN

(I)17:33:32.32 #1067: Out - LAPB UA

(I)17:33:32.32 #0000: 03 73 00 10

verify that the LAPB timer values are consistent with the service provider specifications.

388 CyberSWITCH

Page 388
Image 388
Cabletron Systems CSX1000, CSX1200 manual Connections