USER’S GUIDE

CNTR-TMR:Timed out waiting for TMR <number> interrupt!

The i386s specified timer did not respond during a POST testing its interrupt capabilities. The boot process should continue; however, make note of the error message in the event of a future problem.

Configured adapter # ’x’ type does not exist

The interface adapter indicated does not match the resource configuration in the system. Correct the configuration on the system.

Connection disconnected for license violation

A connection was disconnected because there were more connections in place than allowed with your version of the system software. A larger software version should be ordered.

Could not find port for static route with next hop address <AppleTalk Address>

Contact your distributor or Customer Support.

Could not get Call Restriction information

Contact your Distributor or Customer Support.

Could not get current monthly charges information

Could not get the current monthly call charge information on the system. The call charge feature will be disabled and the problem should be reported. Contact your Distributor or Customer Support.

Could not obtain fcr packet buffer

AppleTalk related. Contact your distributor or Customer Support.

Couldn’t find speech service - <slot #, port #>

An incoming call was received which specified Speech Bearer Service capability. Speech service is not currently supported with the System. Most likely, the incoming call was a wrong number. The system will attempt to treat the call as 56 Kbps data.

Current monthly charges reset for new month

Reported on the first day of the month to indicate that the current monthly call charges value is being reset to zero.

Data link down: Slot=<slot #> Port=<port # > Ces<communication endpoint suffix>

The data link on the specified line is down. If all the data links for a line are down, the line is disabled for switched connection use.

Data link test successful: DSL <port # >, CES 1

This message applies for 1TR6 BRI only. If Layer 1 is established, a test will be done to determine if the data link can be established. This message indicates successful test results.

Data link up: Slot=<slot #> Port=<port #> Ces=<communication endpoint suffix>

The data link on the specified line is active and can be used for establishing switched connections.

DCE Data Rate is invalid on FrStartPVC

The user has configured a data rate which is inconsistent with the application. This can only happen with serial lines such as V.35 where the data rate must be specified in bits-per-second and the configured rate is not valid.

440 CyberSWITCH

Page 440
Image 440
Cabletron Systems CSX1000 CNTR-TMRTimed out waiting for TMR number interrupt, Configured adapter # ’x’ type does not exist