USER’S GUIDE

In - X25 CONNECTION CONFIRMATION ConnId=<connection Id> Access=<access index> RemDteAddr=<x121 address or protocol/route id>

The system has received a connect message from the network. This indicates that a new call is now established.

In - X25 CONNECTION INDICATION ConnId=<connection Id> Access=<access index > RemDteAddr=<x121 address or protocol/route id>

The system has received an incoming call from the network. The system will respond with a connect or a disconnect message.

In - X25 DATA LCN <logical channel number>, <number of bytes> bytes

Data transfer.

In - X25 DCE Clear Conf LCN <logical channel number>, <number of bytes> bytes The DCE is confirming that an SVC call has been cleared by the DTE.

In - X25 DCE Interrupt LCN <logical channel number>, <number of bytes> bytes

An interrupt packet has been received from the DCE. Flow control procedures do not apply to interrupt packets.

In - X25 DCE Intr Conf LCN <logical channel number>, <number of bytes> bytes The DCE is confirming that an interrupt packet has been received.

In - X25 DCE REJ LCN <logical channel number>, <number of bytes> bytes

The DCE has detected a packet sequence error.

In - X25 DCE Restart Conf LCN <logical channel number>, <number of bytes> bytes The DCE is confirming that all virtual circuits have been reset.

In - X25 DCE RNR LCN <logical channel number>, <number of bytes> bytes

The DCE is not ready to receive packets from the DTE.

In - X25 DCE RR LCN <logical channel number>, <number of bytes> bytes

The DCE is acknowledging data packets from the DTE.

In - X25 Diagnostic LCN <logical channel number>, <number of bytes> bytes The DCE is providing a diagnostic packet with a cause and an error code.

In - X25 DISCONNECT CONFIRMA]TION Connid=<connection Id> Access=<access index>

The system has received a disconnect confirmation message from the network. This is usually received after a call disconnect is either initiated by the system or the network.

In - X25 DISCONNECT INDICATION ConnId=< connection Id > Access=< access index > Cause=<cause for disconnect> Diag=<diagnostic for disconnect>

The system has received a disconnect message from the network.

In - X25 Incoming LCN <logical channel number>, <number of bytes> bytes

An SVC call has been received from the DCE.

In - X25 Reset Ind LCN <logical channel number>, <number of bytes> bytes

The DCE is resetting a virtual circuit.

In - X25 Restart Ind LCN <logical channel number>, <number of bytes> bytes

The DCE is resetting all virtual circuits.