USER’S GUIDE

SPID FSM got unidentifiable INFO msg - Slot=<slot #> Port=<port #> Ces=<communication endpoint suffix>

An unexpected information message was received from the network on the indicated line. If you are having trouble establishing calls on this line, the problem should be reported to your phone company.

SSB: Can’t read RTC prior to i960 POSTs

The Real Time Clock became inaccessible before invoking the i960 POSTs. The RTC is used to guard against infinite loops while waiting for the i960 to run its POST tests. The boot process should continue; however, make note of the error message in the event of a future problem.

SSB: Couldn’t read RTC during i960 POSTs

The Real Time Clock became inaccessible during the running of the i960 POSTs. The RTC is used to guard against infinite loops while waiting for the i960 to run its POST tests. The boot process should continue; however, make note of the error message in the event of a future problem.

SSB: i960 I/O memory copy differs from flash image at <address>

After loading the i960 POST tests into the I/O memory, a value unexpectedly changed at the address given.

SSB: i960 Memory read error at <address>, expected <value>, read <value>

While testing the shared memory area (I/O memory and the peripheral buffer memory), an error was detected. The boot process should continue; however, make note of the error message in the event of a future problem.

SSB: i960 POST number not equal to i386’s

The i386 requested the i960 to run a specific POST. Upon receiving the response, from the i960, it was determined that a different POST was actually run.

The boot process should continue; however, make note of the error message in the event of a future problem.

SSB: Post 23 i960host_int_reg FAILURE

The i960 failed its internal register test. The boot process should continue; however, make note of the error message in the event of a future problem.

SSB: Post 24 i960io_int_reg FAILURE

The i960 failed its I/O register test. The boot process should continue; however, make note of the error message in the event of a future problem.

SSB: Post 25 i960io_mod_mem_1 FAILURE

The i960 failed its I/O memory test using the first test pattern. The boot process should continue; however, make note of the error message in the event of a future problem.

SSB: Post 26 i960io_mod_mem_2 FAILURE

The i960 failed its I/O memory test using the second test pattern. The boot process should continue; however, make note of the error message in the event of a future problem.

SSB: Post 27 i960timer_82c54FAILURE

The i960 failed its timer unit test. The boot process should continue; however, make note of the error message in the event of a future problem.

474 CyberSWITCH

Page 474
Image 474
Cabletron Systems CSX1000, CSX1200 manual SSB Can’t read RTC prior to i960 POSTs, SSB Couldn’t read RTC during i960 POSTs