WAN: RBS Not Available on this card.

A RBS debugging command was attempted on a PRI card that is not configured for RBS. Check the card configuration and ensure you have the proper type of card.

Watchdog timeout detected on DM board in slot <slot # >

The Digital Modem card in the specified slot is not functioning properly. Check the board’s configuration in CFGEDIT, reseat the board in its ISA slot, and check any MVIP bus cabling. If everything seems in order and the problem persists, contact your Distributor or Customer Support.

Watchdog timeout detected on WAN board ’x’

The system has detected that the indicated adapter has failed. This is a fatal condition and will cause the card to be reset. Verify the settings on the adapter. If theses are all correct and the problem persists, the indicated adapter card may be faulty. Contact your Distributor or Customer Support.

The following messages are reported when a remote X.25 device's facilities do not match with those configured locally:

X25 facilities error, facilities not allowed in PVC

A facility is configured, for example call deflection, which is not allowed in a PVC. Check your PVC configuration.

X25 facilities error, fast select with restriction on response was required

The fast select with restriction on response is required. Verify that fast select is enabled by both DTE’s and the service provider.

X25 facilities error, bad facility length

The facilities length is missing. Contact your Distributor or Customer Support.

X25 facilities error, invalid facilities length

The length of the facilities packet is invalid. Contact your Distributor or Customer Support.

X25 facilities error, invalid DTE address

The supplied address in a X.25 call packet was invalid. Verify that the local DTE address configuration matches the address supplied by the service provider.

X25 facilities error, facility not allowed

A facility was requested which is not enabled. Verify that the specific facility is enabled by both DTE’s and the service provider.

X25 facilities error, facility length too short

The length of the facilities packet is too short. Contact your Distributor or Customer Support.

X25 facilities error, invalid facilities parameter

A value was chosen for facility which is out of the acceptable range of values for that facility. The range of acceptable values for that facility should be verified at both DTE’s and by the service provider.

X25 facilities error, reverse charging not allowed

The reverse charging facility was selected by the DTE. Verify that reverse charging is enabled by both DTE’s and the service provider.