CAUSE CODES TABLE

Dec Value

Hex Value

Q.931 Cause

 

 

 

34

22

no circuit/channel available

 

 

Indicates that the connection could not be established because there

 

 

was no appropriate channel available to handle the call.

 

 

 

35

23

destination unattainable

 

 

 

37

25

degraded service

 

 

 

38

26

network (WAN) out of order

 

 

Indicates that the destination could not be reached because the

 

 

network was not functioning correctly and that the condition is

 

 

expected to last for a relatively long time. An immediate re-connect

 

 

attempt is likely to be unsuccessful.

 

 

 

39

27

transit delay range cannot be achieved

 

 

 

40

28

throughput range cannot be achieved

 

 

 

41

29

temporary failure

 

 

Indicates that an error has occurred because the network is not

 

 

functioning correctly, but that this problem is likely to be resolved

 

 

shortly.

 

 

 

42

2A

switching equipment congestion (network congestion)

 

 

Indicates that the destination could not be reached because the

 

 

network switching equipment was temporarily overloaded.

 

 

 

43

2B

access information discarded

 

 

Indicates that the network could not provide the requested access

 

 

information.

 

 

 

44

2C

requested circuit/channel not available

 

 

Indicates that the remote equipment could not provide the requested

 

 

channel for an unspecified reason. This may, or may not, be a

 

 

temporary problem.

 

 

 

45

2D

preempted

 

 

 

46

2E

precedence call blocked

 

 

 

47

2F

resource unavailable, unspecified

 

 

Indicates that the requested channel or service was unavailable for

 

 

an unspecified reason. This may, or may not, be a temporary

 

 

problem.

 

 

 

49

31

quality of service unavailable

 

 

Indicates that the requested quality of service (as defined by CCITT

 

 

recommendation X.213) could not be provided by the network. This

 

 

may be a subscription problem.

 

 

 

50

32

requested facility not subscribed

 

 

Indicates that the remote equipment supports the requested

 

 

supplementary service but that this is available only by subscription.

 

 

 

51

33

reverse charging not allowed

 

 

 

Workgroup Remote Access Switch 631