USER’S GUIDE

CONFIGURING TCP

If you have selected TCP as your IP protocol, a screen similar to the following is displayed. Note that the following TCP defaults constitute a wild card match for any TCP packet:

PACKET

TYPE "Type_One":

 

 

1)

IP Source Address

AND 0.0.0.0 EQUAL 0.0.0.0

2)

IP Destination Address

AND 0.0.0.0 EQUAL 0.0.0.0

3)

IP Protocol

EQUAL TCP

4)

TCP

Source Port

RANGE 0

- 65535

5)

TCP

Destination Port

RANGE 0

- 65535

6)

TCP

Control

ANY

 

Select function from above or <RET> for previous menu:

1.Select TCP Source Port. Note that the ports are specified in terms of an operator.

2.Select a comparison operator.

3.If you have chosen the comparison operator of “RANGE”, you will be prompted for upper-range and lower-range values. If you have chosen a comparison operator other than “RANGE”, you will be prompted for a specific TCP port number.

4.Select TCP Destination Port. Note that the ports are specified in terms of an operator.

5.Select a comparison operator.

6.If you have chosen the comparison operator of “RANGE”, you will be prompted for upper-range and lower-range values. If you have chosen a comparison operator other than “RANGE”, you will be prompted for a specific TCP port number.

7.Select TCP Control.

8.Specify a control value (any, established, or not established).

CONFIGURING UDP

If you have selected UDP as your IP protocol, a screen similar to the following is displayed. Note that the following UDP defaults constitute a wild card match for any UDP packet:

 

 

 

 

 

 

 

 

PACKET TYPE "Type_One":

 

 

 

 

 

1)

IP Source Address

AND 0.0.0.0

EQUAL 0.0.0.0

 

 

2)

IP Destination Address

AND 0.0.0.0

EQUAL 0.0.0.0

 

 

3)

IP Protocol

EQUAL UDP

 

 

 

4)

UDP Source Port

RANGE 0

- 65535

 

 

5)

UDP Destination Port

RANGE 0

- 65535

 

 

Id of the item to change, <RET> to accept

changes or <CTRL-C> to cancel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Select UDP Source Port. Note that the ports are specified in terms of an operator.

2.Select a comparison operator.

244 CyberSWITCH

Page 244
Image 244
Cabletron Systems CSX1000, CSX1200 manual Specify a control value any, established, or not established