2-1059
Catalyst 6500 Series Switch Command Reference—Release7.6
78-15328-01
Chapter2 Catalyst 6500 Series Switch and ROM Monitor Commands show system
Syslog Dump Syslog File
------------------------ -----------------------
enabled bootflash:sysloginfo
Console>
Table 2 -91 describes the fields in the show system command output.
Table2-91 show system Command Output Fields
Field Description
PS1-Status Status of power supply 1 (ok, fan failed, faulty, or none).
PS2-Status Status of power supply 2 (ok, fan failed, faulty, or none).
Fan-Status Status of the fan (ok, faulty, or other).
Temp-Alarm Status of whether the temperature alarm is off or on.
Sys-Status System status (ok or faulty). Corresponds to system LED stat us.
Uptime d, h:m:s Amount of time in days, hours, minutes, and seconds, that the
system has been up and running.
Logout Amount of time after which an idle session is disconnected.
PS1-Type Part number of the power supply.
PS2-Type Part number of the redundant power supply, if present.
Modem Status of the modem status (enable or disable).
Baud Baud rate to which the modem is set.
Traffic Current traffic percentage.
Peak Peak percentage of traffic on the backplane.
Peak-Time Time stamp when peak percentage was recorded.
PS1 Capacity Power supply 1 maximum capacity.
PS2 Capacity Power supply 2 maximum capacity.
PS Configuration Power supply configuration.
System Name System name.
System Location System location.
System Contact System contact informa tion.
CC Country code string.
Core Dump Status of the core dump feature (enable or disable).
Core File Flash file device and core dump file name.
Syslog Dump Status of the syslog dump feature (enable or disable) .
Syslog File Flash file device and syslog dump file name.
Backplane-Traffic Current traffic percentage.
Fabric Chan Number of the fabric channel.
Input Percentage of fabric channel utilization for input.
Output Percentage of fabric channel utilization for output.