Chapter2 Catalyst 6500 Series Switch and ROM Monitor Commands set snmp extendedrmon netflow
set snmp extendedrmon netflow
To enable or disable the SNMP extended RMON support for the NAM module, use the set snmp
extendedrmon netflow command.
set snmp extendedrmon netflow {enable | disable} {mod}
Syntax Description
Defaults The default is SNMP-extended RMON NetFlow is disabled.
Command Types Switch command.
Command Modes Privileged.
Examples This example shows how to enable SNMP-extended RMON NetFlow support :
Console> (enable) set snmp extendedrmon netflow enable 2
Snmp extended RMON netflow enabled
Console> (enable)
This example shows how to disable SNMP-extended RMON NetFlow support:
Console> (enable) set snmp extendedrmon netflow disable 2
Snmp extended RMON netflow disabled
Console> (enable)
This example shows the response when the SNMP-extended RMON NetFlow feature is no t suppor ted:
Console> (enable) set snmp extendedrmon enable 4
NAM card is not installed.
Console> (enable)
Related Commands se t snmp rmon
show snmp
enable Enables the extended RMON support.
disable Disables the extended RMON support.