show fabric channel
Examples This example shows how to display fabric channel counter informatio n f or a sp eci fic modul e:
Console> show fabric channel counters 2
Channel 0 counters:
0 rxErrors = 0
1 txErrors = 0
2 txDropped = 0
Console>
This example shows how to display fabric channel utilization information:
Console> show fabric channel utilization
Fab Chan Input Output
-------- ----- ------
0 0% 0%
1 0% 0%
2 0% 0%
3 0% 0%
.
.
.
15 0% 0%
16 0% 0%
17 0% 0%
Console>
This example shows how to display switch mode and fabric channel status:
Console> show fabric channel switchmode
Global switching mode: flow through
Module Num Fab Chan Fab Chan Switch Mode Channel Status
------ ------------ -------- ------------ --------------
2 1 0, 1 flow through ok
3 0 n/a n/a n/a
5 18 0, 0 n/a unknown
5 18 1, 1 n/a ok
.
.
.
5 18 15, 15 n/a unknown
5 18 16, 16 n/a unknown
5 18 17, 17 n/a unknown
16 0 n/a n/a n/a
Console>
Table 2 -30 describes the fields in the show fabric channel output.
Table2-30 show fabric channel Command Output Fields
Field Description
rxErrors Number of received errors.
txErrors Number of transmitted errors.
txDropped Number of dropped transmitted packets.
Input Percentage of input traffic utilization.
Output Percentage of output traffic utilization.
Num Fab Chan Number of fabric channels associated with the module.
Global switching mode Global switching mode of the switch (flow through, truncated, and
compact).