Catalyst 6500 Series Switch Command Reference—Release7.6
78-15328-01
Chapter2 Catalyst 6500 Series Switch and ROM Monitor Commands set test diaglevel
set test diaglevelTo set the diagnostic level, use the set test diaglevel command.
set test diaglevel {complete | minimal | bypass}
Syntax Description
Defaults The default is minimal diagnostics. See the “Usage Guidelines” section for more information about the
three diagnostic levels.
Command Types Switch command.
Command Modes Privileged.
Usage Guidelines Setting the diagnostic level determines the level of testing that occurs when the system or module is
reset. The three levels are as follows:
•complete—This level runs all tests.
•minimal—This level runs only EARL tests for the supervisor engine and loopback tests for all ports
in the system.
•bypass—This level skips all tests.
Note Although the default is minimal, we recommend that you set the diagnostic level at complete.
Examples This example shows how to set the diagnostic level to complete:
Console> (enable) set test diaglevel complete
Diagnostic level set to complete.
Console> (enable)
This example shows how to set the diagnostic level to bypass:
Console> (enable) set test diaglevel bypass
Diagnostic level set to bypass.
Console> (enable)
Related Commands show test
complete Specifies complete diagnostics.
minimal Specifies minimal diagnostics.
bypass Specifies bypass diagnostics.