2-439
Catalyst 6500 Series Switch Command Reference—Release7.6
78-15328-01
Chapter2 Catalyst 6500 Series Switch and ROM Monitor Commands set power redundancy
set power redundancyTo turn redundancy between the power supplies on or off, use the set power redundancy command.
set power redundancy {enable | disable}
Syntax Description
Defaults The default is power redundancy is enabled.
Command Types Switch command.
Command Modes Privileged.
Usage Guidelines In a system with dual power supplies, this command turns redundancy on or off between the power
supplies. In a redundant configuration, the power available to the system is the maxi mum power
capability of the weakest power supply.
In a nonredundant configuration, the power availab le to the sy stem is the s um of the po wer capabili ty of
both power supplies.
Examples This example shows how to activate redundancy between power supplies:
Console> (enable) set power redundancy enable
Power supply redundancy enabled.
Console> (enable)
This example shows how to deactivate redundancy between power supplies:
Console> (enable) set power redundancy disable
Power supply redundancy disabled.
Console> (enable)
Related Commands s how environment
show system
enable Activates redundancy between the power supplies.
disable Deactivates redundancy between the power supplies.