2-789
Catalyst 6500 Series Switch Command Reference—Release7.6
78-15328-01
Chapter2 Catalyst 6500 Series Switch and ROM Monitor Commands show mls cef interface
show mls cef interfaceTo display MSFC VLAN information, use the show mls cef interface command.
show mls cef interface [vlan]
Syntax Description
Defaults This command has no default settings.
Command Types Switch command.
Command Modes Normal.
Usage Guidelines This command is supported on Catalyst 6500 series switches configured with the Supervisor Engine 2
with Layer 3 Switching Engine II (PFC2) only.
Examples This example shows how to display Cisco Express Forwarding (CEF) interface s:
Console> (enable) show mls cef interface
Module 16: vlan 1, IP Address 21.0.0.194, Netmask 255.0.0.0
MTU = 1500, State = up, ICMP-Unreach = enabled, ICMP-Redirect = enabled
Unicast RPF = disabled
Module 16: vlan 43, IP Address 43.0.0.99, Netmask 255.0.0.0
MTU = 1500, State = down, ICMP-Unreach = disabled, ICMP-Redirect = disabled
Unicast RPF = disabled
Module 16: vlan 44, IP Address 44.0.0.99, Netmask 255.0.0.0
MTU = 1500, State = down, ICMP-Unreach = disabled, ICMP-Redirect = disabled
Unicast RPF = disabled
Module 16: vlan 45, IP Address 45.0.0.99, Netmask 255.0.0.0
MTU = 1500, State = up, ICMP-Unreach = enabled, ICMP-Redirect = enabled
Unicast RPF = disabled
Module 16: vlan 46, IP Address 46.0.0.99, Netmask 255.0.0.0
MTU = 1500, State = up, ICMP-Unreach = enabled, ICMP-Redirect = enabled
Unicast RPF = disabled
Module 16: vlan 47, IP Address 47.0.0.99, Netmask 255.0.0.0
MTU = 1500, State = down, ICMP-Unreach = disabled, ICMP-Redirect = disabled
Unicast RPF = disabled
Module 16: vlan 48, IP Address 48.0.0.99, Netmask 255.0.0.0
MTU = 1500, State = down, ICMP-Unreach = disabled, ICMP-Redirect = disabled
Unicast RPF = disabled
Module 16: vlan 49, IP Address 0.0.0.0, Netmask 0.0.0.0
MTU = 1500, State = down, ICMP-Unreach = disabled, ICMP-Redirect = disabled
Unicast RPF = disabled
Console> (enable)
vlan (Optional) Number of the VLAN; valid values are from 1 to 4094.