Digi NS9215 manual Received or a buffer close event occurs, such as end

Models: NS9215

1 517
Download 517 pages 25.29 Kb
Page 423
Image 423

S E R I A L C O N T RO L M O D U L E : H D L C

. . .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wrapper Configuration register.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.

Register

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31

30

29

28

27

26

25

24

23

22

 

21

20

 

19

18

17

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reserv

RXEN

TXEN

MODE

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

RX

 

TX

 

 

ed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FLUSH

 

FLUSH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

14

13

12

11

10

9

8

 

 

7

6

 

5

4

 

3

2

1

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RXBYTES

RX

CRC

 

 

 

Reserved

 

 

 

 

RL

 

LL

 

 

 

Reserved

 

 

 

CLOSE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Register bit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

assignment

Bits

 

Access

Mnemonic

Reset

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D31

 

N/A

 

Reserved

 

N/A

 

 

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D30

 

R/W

 

RXEN

 

0

 

 

0

Disable wrapper function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Enable wrapper to process receive characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D29

 

R/W

 

TXEN

 

0

 

 

0

Disable wrapper transmitter function

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Enable wrapper to process transmit characters

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D28

 

R/W

 

MODE

 

0

 

 

Applies only to UART channel C.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

UART mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

HDLC mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D27:18

N/A

 

Reserved

 

N/A

 

 

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D17

 

R/W

 

RXFLUSH

0

 

 

Resets the contents of the 64-byte RXFIFO.

 

 

 

 

 

 

 

 

 

 

 

 

 

Write a 1, then a 0 to reset the FIFO.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D16

 

R/W

 

TXFLUSH

0

 

 

Resets the contents of the 64-byte TX FIFO.

 

 

 

 

 

 

 

 

 

 

 

 

 

Write a 1, then a 0 to reset the FIFO.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D15:14

R

 

RXBYTES

00

 

 

Indicates how many bytes are pending in the wrapper.

 

 

 

 

 

 

 

 

 

 

 

The wrapper writes to the RX FIFO only when 4 bytes are

 

 

 

 

 

 

 

 

 

 

 

received or a buffer close event occurs, such as end of

 

 

 

 

 

 

 

 

 

 

 

frame.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D13

 

R/W

 

RXCLOSE

0

 

 

Allows software to close a receive buffer. Hardware

 

 

 

 

 

 

 

 

 

 

 

clears this bit when the buffer has been closed.

 

 

 

 

 

 

 

 

 

 

 

 

 

0

Idle or buffer already closed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Software initiated buffer close

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D12

 

R/W

 

CRC

 

0

 

 

Controls whether the HDLC transmitter hardware sends

 

 

 

 

 

 

 

 

 

 

 

CRC bytes before the closing flag.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

Send CRC bytes before the closing flag

 

 

 

 

 

 

 

 

 

 

 

 

 

1

Do not send CRC bytes before the closing flag;

 

 

 

 

 

 

 

 

 

 

 

 

handled by software

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D11:06

N/A

 

Reserved

 

0

 

 

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D05

 

R/W

 

RL

 

0

 

 

Remote loopback

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Provides an internal remote loopback feature. When the

 

 

 

 

 

 

 

 

 

 

 

RL field is set to 1, the receive HDLC data signal is

 

 

 

 

 

 

 

 

 

 

 

connected to the transmit HDLC data signal.

 

 

www.digiembedded.com