Digi NS9215 manual I M a n a g e m e n t I n d i c a t o r s r e g i s t e r, MII read data, Miilf

Models: NS9215

1 517
Download 517 pages 25.29 Kb
Page 299
Image 299

E T H E R N E T C O M M U N I C A T I O N M O D U L E

. . .

 

 

 

 

 

 

 

 

 

 

 

MII Management Indicators register.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

.

Register

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MRDD

 

 

 

 

 

 

 

 

Register bit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

assignment

Bits

 

Access

 

Mnemonic

Reset

 

Description

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D31:16

 

N/A

 

Reserved

 

N/A

 

N/A

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D15:00

 

R

 

MRDD

 

0x0000

 

MII read data

 

 

 

 

 

 

Read data is obtained by reading from this register after an MII Management read cycle. An MII Management read cycle is executed by loading the MII Management Address register, then setting the READ bit to 1 in the MII Management Command register. Read data is available after the BUSY bit in the MII Management Indicators register returns to 0.

M I I M a n a g e m e n t I n d i c a t o r s r e g i s t e r

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Address: A060 0434

Register

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reserved

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reserved

 

 

 

 

 

MIILF

N

SCAN

BUSY

 

 

 

 

 

 

 

 

 

 

 

VALID

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Register bit

assignment

Bits

Access

Mnemonic

Reset

Description

 

 

 

 

 

 

 

D31:04

N/A

Reserved

N/A

N/A

 

 

 

 

 

 

 

D03

R

MIILF

0

MII link failure

 

 

 

 

 

When set to 1, indicates that the PHY currently has a

 

 

 

 

 

link fail condition.

www.digiembedded.com

299

Page 299
Image 299
Digi NS9215 manual I M a n a g e m e n t I n d i c a t o r s r e g i s t e r, MII read data, Miilf, MII link failure

NS9215 specifications

The Digi NS9215 is a powerful solution designed for industrial applications that require reliable connectivity and robust performance. Built on a foundation of advanced technologies, the NS9215 serves as a versatile networking device that meets the demands of automation, remote monitoring, and data acquisition.

One of the standout features of the Digi NS9215 is its multi-protocol support. It is capable of handling various communication protocols, including Ethernet, Serial, and Wireless, making it ideal for integration into heterogeneous environments. This flexibility enables users to connect legacy devices to modern networks seamlessly, facilitating smoother data communication across different platforms.

The NS9215 is equipped with powerful processing capabilities, featuring an integrated processor that ensures efficient data handling. This enables the device to perform complex data tasks without compromising performance. Its high-speed connectivity options also allow for rapid data transmission, which is crucial for real-time applications in industrial settings.

Another critical characteristic of the Digi NS9215 is its reliability in harsh environments. Built to withstand extreme temperatures, humidity, and electrical interference, this device assures consistent operation even in challenging conditions. Its rugged design minimizes the risk of failure, making it suitable for deployment in various industrial environments.

Security is a top priority for the Digi NS9215. It comes with advanced security features that protect sensitive data during transmission and prevent unauthorized access. Employing encryption protocols and secure authentication methods, the NS9215 ensures that data integrity and confidentiality are maintained throughout its operation.

The user-friendly interface of the NS9215 allows for easy configuration and management. This ease of use reduces the time required for installation and setup, enabling quick deployment in field operations. Additionally, remote management capabilities enhance operational efficiency, allowing users to monitor device performance and make adjustments from anywhere.

Furthermore, the NS9215 supports extensive scalability options. As organizations grow and evolve, the ability to scale up or adapt the networking capabilities becomes essential. With its modular design, the NS9215 can easily accommodate additional devices and protocols, ensuring longevity and continued relevance in a rapidly changing technological landscape.

In conclusion, the Digi NS9215 is a robust networking device designed for a wide range of industrial applications. Its multi-protocol support, reliability, security features, user-friendly interface, and scalability make it a valuable addition to any industrial network infrastructure, delivering performance and efficiency that businesses can depend on for critical operations.