Troubleshooting and Pen Alignment of Recorder without Display

7.3.2 Recorder Failure Troubleshooting

Procedure

Table 7-2explains how to troubleshoot recorder failure symptoms.

Table 7-2 Troubleshooting Recorder Failure Symptoms

Step

What to do

How to do it or

 

 

where to find the instructions

 

 

 

1

Check the supply voltage.

Measure the line voltage across the line and neutral

 

 

connections at TB1 on the printed circuit assembly

 

 

(PCA) on the right (for pen 1).

 

 

 

2

Check the connections to TB1 on the

Refer to ac wiring procedures in Section 2 –

 

pen 1 PCA.

Installation.

 

 

 

3

Check the system for brown-outs,

Refer to Section 2 – Installation.

 

heavy load switching, etc.; and

 

 

conformance to installation instructions.

 

 

 

 

4

Replace the PCA for pen 1.

Refer to the replacement procedures in Section 9 –

 

 

Replacing Hardware Assemblies.

 

 

 

12/03

DR4300 Circular Chart Recorder Product Manual

165

Page 177
Image 177
Honeywell DR4300 manual Recorder Failure Troubleshooting, Troubleshooting Recorder Failure Symptoms