Troubleshooting and Pen Alignment of Recorder with Display

8.5.4 Chart Rotation Troubleshooting

Procedure

Table 8-8explains how to troubleshoot a chart rotation problem.

Table 8-8 Troubleshooting Chart Rotation Failure Symptoms

Step

What to do

How to do it or

 

 

where to find the instructions

 

 

 

1

Check the chart installation.

Turn the chart until the desired time line on the

 

 

chart is aligned with the time index on the chart

 

 

plate and pen 1 before closing the locking clip on

 

 

the hub. Push down on the lifter to return the

 

 

pen(s) to the chart.

 

 

CAUTION: Do not try to rotate the hub

 

 

 

2

Check the configured chart speed value

Refer to Section 4 – Configuration, Startup, and

 

and change it, if required.

Operation of Recorder with Display.

 

 

 

3

Run the step test.

Refer to Section 4 – Configuration, Startup, and

 

 

Operation of Recorder with Display (Subsection

 

 

4.4.3).

 

 

 

4

Check the motor cable plug connection at

Power down the recorder, then visually examine

 

connector P3 on the printed circuit

the plug and re-seat it.

 

assembly for pen 1.

 

 

 

 

5

Replace the chart motor.

Refer to the replacement procedure in Section 9

 

 

– Replacing Hardware Assemblies.

 

 

 

6

Replace the printed circuit board for pen

Refer to the replacement procedure in Section 9

 

1.

– Replacing Hardware Assemblies.

 

 

 

12/03