Installation

2.3.2 Mounting Flush in Panel (New Panel Cutout)

Procedure

Refer to Figure 2-3and follow the procedure in Table 2-2to make a new cutout in a panel and mount your recorder in the cutout.

Table 2-2 Mounting Flush in a New Panel Cutout

Step

Action

1At the appropriate location, make a square cutout in the panel. Cutout dimensions should be 322.56 mm ± 1.52 mm x 322.56 mm ± 1.52 mm [12.7 in ± 0.060 in x 12.7 in ± 0.060 in]. See Figure 2-3.

2Orient the recorder case properly and slide it into the cutout from the front of the panel. Support the recorder as shown in Steps 3 and 4.

3Refer to Figure 2-3.From the back of the panel, attach a mounting bracket to each side of the recorder case using a 1/4-20 x 1/2-inch hex screw for each bracket (mounting hardware supplied with recorder). Leave the screws slightly loose so you can adjust the brackets.

4While holding the recorder firmly against the panel, slide each bracket against the back of the panel and tighten the screws.

Hex screw,

1/4-20

x

1/2 inch and

washer

21406

Figure 2-3 Mounting Flush in a New Panel Cutout (Rear View)

12/03

DR4300 Circular Chart Recorder Product Manual

17

Page 29
Image 29
Honeywell DR4300 Mounting Flush in Panel New Panel Cutout, Procedure, Mounting Flush in a New Panel Cutout, Step Action