Honeywell DR4300 manual Panel Mounting Recorder with NEMA4 or Heavy Duty door

Models: DR4300

1 262
Download 262 pages 56.21 Kb
Page 30
Image 30

DR4300 Circular Chart Recorder

2.3.3 Panel Mounting Recorder with NEMA4 or Heavy Duty door

Refer to Figure 2-4and follow the procedure in Table 2-3to panel mount your recorder if it has a NEMA4 or Heavy Duty door.

Table 2-3 Procedure for Mounting Recorder with NEMA4 or Heavy Duty Door

Step

Action

 

 

1

Place the panel gasket onto the rear flange of the recorder case.

 

 

2

Install four #8-32 screws on each of the three mounting brackets so the ends of the screw

 

threads are flush with the face of the bracket.

 

NOTE: Screw heads to be flange side of brackets.

 

 

3

Insert the case with gasket into the panel opening.

 

 

4

Install one left hand and one right hand bracket with 1/4 x 3/8 long bolts and lockwashers on

 

each side of the case.

 

NOTE: The notch on each bracket should be facing upward towards the top of the unit.

 

Do not tighten the hex bolts at this time.

 

 

5

Install the remaining right hand bracket on the top with the 1/4 x 3/4 long bolt and lockwasher.

 

Do not tighten the bolt at this time.

 

 

6

Place a screwdriver blade on the notch of each bracket and firmly tap so that each bracket

 

firmly mates the case with gasket to the panel.

 

NOTE: Keep brackets parallel to case. Tighten the three 1/4 hex bolts to hold the brackets in

 

place.

 

 

7

Start to tighten the #8-32 x 1/2 screws on the right side bracket. Alternate screws at opposite

 

ends until all four screws have a minimum of 10 lb-in of torque applied. Do the same to both

 

the left side and top brackets.

 

When completed all twelve screws should have a minimum of 10 lb-in of torque applied. This

 

assures the case and panel gasket are adequately sealed against the panel.

 

 

18

DR4300 Circular Chart Recorder Product Manual

12/03

Page 30
Image 30
Honeywell DR4300 manual Panel Mounting Recorder with NEMA4 or Heavy Duty door, Do not tighten the hex bolts at this time